EasyManua.ls Logo

ABB SCK - Using the EMERGENCY-STOP Switch

ABB SCK
244 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OI/SCK
-EN Rev. E Operating instruction SCK Gas Sampling System 147
Using the EMERGENCY-STOP switch
Observe all safety instructions in the section
Safety regulations for operation
on page 136
when performing this work.
The EMERGENCY STOP switch is used to interrupt probe movement immedi-
ately in the event of danger to personnel. Actuating the switch disables all
mechanisms serving to protect the gas sampling probe. The gas sampling
probe interrupts its movement immediately and in any position.
The EMERGENCY STOP switch is used to interrupt probe movement in the
event of danger to personnel. The probe is only retracted out of the rotary kiln
after pressing the service switch.
What to do after pressing the EMERGENCY STOP switch:
Step Procedure
1
Remove danger.
2
Make sure that
the danger cannot occur again,
no-one is standing in the area of probe retractor travel.
3
Unlock the EMERGENCY STOP switch by turning the back ring in
the direction of the arrow.
4
Actuate service switch in control cabinet (i.e. turn to
ON
posi-
tion).
WARNING! Actuating the service switch moves the probe out of
the kiln. Do not stand in the area of travel of the probe or
probe carriage until the probe has reached its end position
and the warning lamps go out.
Result: The gas sampling probe is automatically retracted out
of the kiln, the controller displays the
Maintenance
message.
5
Turn service switch back to the initial position (
OFF
).
Introduction
Instructions

Table of Contents

Other manuals for ABB SCK

Related product manuals