EasyManua.ls Logo

ABB SCK - Checking General System Condition

ABB SCK
244 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OI/SCK
-EN Rev. E Operating instruction SCK Gas Sampling System 141
Checking general condition
Observe all safety instructions in the section
Safety regulations for operation
on page 136
when performing this work.
When the gas sampling system is in operation, monitor the general condition
of the system on a daily basis:
Module Procedure
Retractor in-
cluding probe
Check general condition of retractor with regard to the
following:
general damage
missing or loose covers
visible damage to electric cables
hose and pipe leaks
drive chain:
chain tension
chain link wear
compressed-air oiler
damage
leaks
oil level
gas sampling probe:
signs of wear (e.g. polished metal surfaces)
Cooling module Check general condition of cooling module with regard
to the following:
general damage
missing or loose covers
visible damage to electric cables
hose and pipe leaks
Control cabinet Check general condition of control cabinet with regard
to the following:
general damage
missing or loose covers
visible damage to electric cables
dripping water or other liquids
Compressed-air
tank(optional)
Check general condition of compressed-air tank with
regard to the following:
visible damage
If there are any defects that impact safety, inform the responsible mainte-
nance personnel. If cleaning is necessary, follow the instructions in
Checking
the condition of the system, cleaning the system
on page 163.
Condition of the
sampling system

Table of Contents