OI/SCK
-EN Rev. E Operating instruction SCK Gas Sampling System 199
How to check drive tension:
Step
Procedure
1
Check drive chain tension.
Target requirement: The upper chain is adequately tensioned
when you can pull it down approx. 4-5 cm by hand.
2
If the chain droops or if you can pull it down further:
Tension the drive chain with the chain tensioner in the probe
carriage using the adjustment nuts
(1)
such that the upper part
of the chain does not droop onto the lower part of the chain.
Note: Ensure that the drive chain is not twisted. Also, ensure
adequate tightening of the adjustment nuts.
3
Unlock EMERGENCY STOP switch, turn service switch back to
OFF
position and insert probe again using the controller.
WARNING! Probe moves into the kiln. Do not stand in the area
of travel of the probe or probe carriage until the probe is
completely inserted into the kiln and the warning lamps go
out.