74 Operating instruction SCK Gas Sampling System OI/SCK-EN Rev. E
Danger Where / in what situa-
tion does the danger
Preventive action
Risk of burning due
to falling or spall-
ing material.
After the probe moves
out of the rotary kiln,
hot material may fall or
spall off the probe.
Never enter the danger
area around the retractor
during operation.
Do not approach the
retracted probe until it
has cooled down.
If it is unavoidable to
approach the hot probe,
wear a face mask against
heat, heat-proof gloves
and protective welder's
clothing.
Danger due to
harmful gases, jet
flames
Due to gases escaping
from the duct opening
of the rotary kiln
Only enter the danger
area around the retractor
when the shutter is
closed.
Lock the shutter before
commencing work.
Ensure adequate ventila-
tion of the work place.
If work is unavoidable in
the area of the duct open-
ing, wear respiratory pro-
tection in addition to the
general protective
due to hot cooling
water
cooling water system,
particularly:
ventilation open-
ings
the cooling water system
until it has cooled down.
harmful anti-freeze
the cooling system
cooling water and the an-
ti-freeze.
Wash any cooling water
or anti-freeze off the skin
immediately with water
and soap.
If cooling water or anti-
freeze gets in the eyes
despite protective glass-
es, rinse them thoroughly
under running water,
holding the eyelids open.
Observe instructions in
the anti-freeze manufac-
turer's safety data sheet.