SensyMaster FMT430, FMT450 THERMAL MASS FLOWMETER | OI/FMT430/450-EN REV. B 125
Menu: Totalizer
Menu / parameter
Description
Totalizer
...Operation
Selection of submenu ‘
...Operation’ using .
...Reset Totalizer
Selection of submenu ‘...Reset Totalizer’ using .
...Preset Totalizer
Selection of submenu ‘
...Preset Totalizer’ using .
...FillMass
Selection of submenu ‘...FillMass’ using .
Totalizer / ...Operation
Start all Totalizer
Starts all
counters.
Stop all Totalizer
Stops all counters.
Totalizer /
...Reset Totalizer
All Totalizer
Resets all totalizers to zero.
Massflow Qm
Reset all mass totalizers to zero.
Volumeflow Qv@
Reset all standard volume totalizers to zero.
Totalizer / ...Preset Totalizer
Massflow Qm
Input from meter readings (e.g. when replacing the transmitter).
Volumeflow Qv@
Totalizer /
...FillMass
Batch Process Value
Selection of process variable used during the filling process.
Off: Filler deactivated.
VolumeFlow@: Standard flow rate.
Mass Flow: Mass flow.
Preset Batch Total.
Sets the fill quantity using the selected unit.
When the defined fill quantity is reached, the configured binary output is activated.
Note
Before setting the
fill quantity, the corresponding process value must be selected with the parameter ‘Batch Process Value’.
Reset Cur.Batch Tot.
Resets the current fill quantity.
Start Batching
Manual start of the filling function.
Alternatively, the digital input can
be configured for starting / stopping the fill operation.
Current Batch Total
Display of the current fill quantity.
Once a fill operation has been started, the quantity already filled is shown here. The counter restarts at zero for each fill
operation initiated and then counts up to the set fill quantity.
Stop Batching
Manual stop of the filling function.
Alternatively, the digital input can be configured for starting / stopping the fill operation.
Current Batch Counts
Display of the number of fill operations since the last reset.
Reset Batch Counts
Sets the parameter ‘
Current Batch Counts’ to zero.
...Quantity
Select the ‘...Quantity’ submenu.