130 SensyMaster FMT430, FMT450 THERMAL MASS FLOWMETER | OI/FMT430/450-EN REV. B
10 Diagnosis / error messages
Overview
Process values
Counter
Current output
Priority
Error text
Qm [%, unit]
Qv [%, unit]
Density [g/cm
3
]
Temperature [°C]
Concentration [%]
Net mass flow
Standard density
g/cm
3
]
Standard volume
[20
°C]
All counters
76
All totalizer stopp. 0 0 0 0 0 0 0
74
Totalizer reset. Reset of one or
more Totalizers.
72
Simulation is on! Simulating
process/output value
70
An alarm is simulated.
65
CO31/32 readbackcurrent
deviates
60
Sensor heat emission limit.
59
Reserved 36 0 0 0 0
58
Invalid Sensor configuration
2)
1
2)
2)
2)
2)
57
Sensor temperature out of range.
1)
1)
1)
20
1)
1)
1)
1)
52
Curr.Out 31/32 is saturated. Current output 31 /32 /U
CO
only:
HOLD
, ,
51
Curr.Out V1/V2, V3/V4 saturated Current output V1 / V2, V3 /
V4:
HOLD, ,
49
Option Card 1 com error. Only with current output V1 /
V2
,
48
Option Card 2 com error. Only with current output V3 /
V4:
,
47
Dig.Out 41/42 is saturated.
46
Mass flowrate exceeds limits.
44
Volume flowrate exceeds limits.
43
Reserved 37
42
Medium temperat exceeds limits.
41
Std.Volume flow exceeds limits.
40
Sensor soiling detected.
38
Sensor memory defective.
37
NV chips defect on Motherboard.
32
Curr.Out 31/32 not calibrated.
31
Curr.Out V1/V2 not calibrated.
30
Curr.Out V3/V4 not calibrated.
28
Display value is<1600h at Qmax.
26
Maintenance interval is reached
24
Device not calibrated.
20
Communicat. card not
responding