ADTECH4 SeriesCNC Maintenance Manual
Output signal follows the hertz specified by P1.024 in working state, and
used for oil supply devices. If it is set to 0, the system will keep low
output level.
025
Auto-zero mode configuration (BIT)
Range
:
Unit
:
Authority
:
Operation admin
Default
:
Z XYABC
Effective time
:
Instant
Note
:
Set the zero sequence of each axis; up to three sections can be set.
026
Arc Acc.for Radii
027
Arc Acc.for Speed
Range
:
Unit
:
Coefficient
Authority
:
Operation admin
Default
:
50, 100
Effective time
:
Instant
Note
:
Used to restrict the arc processing speed automatically. This parameter is
valid in pretreatment mode.
The bigger the radius coefficient is, the lower the arc speed is.
The bigger the acceleration coefficient is, the higher the arc speed is.
028
Pretreatment Code Set
Range
:
100~5000
Unit
:
Instruction line
Authority
:
Operation admin
Default
:
500
Effective time
:
Instant
Note
:
Set the pre-reading instruction lines; if the pretreatment processing
pauses and pre-reads, please increase this value to pre-read more
instructions.