EasyManua.ls Logo

Adtech ADTECH4 CNC Series - Page 109

Adtech ADTECH4 CNC Series
201 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ADTECH4 SeriesCNC Maintenance Manual
Authority
:
Operation admin
Default
:
0
Effective time
:
Instant
Note
:
Control mode corresponding to principal axis S code (frequency
conversion mode)
0 : Analog output
1: Section speed regulation (4-digit code determined by output port
configured by principal axis parameters P6.014 ~ P4.017), as below:
P6.014------S0
P4.015------S1
P4.016------S2
P4.017------S3
In analog output mode, the analog voltage is:
VS/MaxRPM
S is the rotation set by the user, and MaxRPM is the maximum rotation
of principal axis set by the parameter (P4.017);
In switching quantity mode, constitute block 0-15 according to four-digit
code to output; S code value is restricted to 0-15;
022
Lubricant pressure schedule open setting (min)
023
Lubricant pressure holding time setting (sec)
024
Lubricant control output frequency (Hz)
Range
:
Unit
:
Authority
:
Operation admin
Default
:
0
Effective time
Note
:
:
Instant
Set the schedule start and holding time of the automatic oil pump of the
system
Schedule open setting is that the oil pump outputs (P4.056 Lubricant
output port No.) when the timing reaches specified value after the
system starts and times.
Output signal stops keeping for the seconds specified by P1.053 (reverse
phase).

Table of Contents

Related product manuals