ADTECH4 SeriesCNC Maintenance Manual
Y axis maximum constraint speed (mm/sec)
Z axis maximum constraint speed (mm/sec)
4 axes maximum constraint speed (mm/sec)
B axis maximum constraint speed (mm/sec)
C axis maximum constraint speed (mm/sec)
Range
:
1~90000
Unit
:
Authority
:
Super admin
Default
:
90000
Effective time
:
Instant
Note
:
Used to configure the restriction acceleration of every axis during
pretreatment processing.
No matter which parameter, the lower the setting is, the slower the
processing speed is; vice versa.
The setting value should be as high as possible if each axis permits.
This parameter is valid when the general parameter P1.018 (speed
optimization constraint mode) is set to Speed or Speed1.
013
Effective voltage level for servo X axis alarm
Effective voltage level for servo Y axis alarm
Effective voltage level for servo Z axis alarm
Effective voltage level for servo 4 axes alarm
Effective voltage level for servo B axis alarm
Effective voltage level for servo C axis alarm
014
Effective voltage level for servo X axis reset
Effective voltage level for servo Y axis reset
Effective voltage level for servo Z axis reset
Effective voltage level for servo 4 axes reset
Effective voltage level for servo B axis reset
Range
:
0~1
Unit
:
LOGIC VOLTAGE LEVEL