ADTECH4 SeriesCNC Maintenance Manual
Default
:
0, 1
Effective time
:
Instant
Note
:
Adapt to the interface parameters of selected servo drive; please refer to
interface voltage level description of servo for specific parameter
settings.
0015
Servo X axis Z phase home enable
Servo Y axis Z phase home enable
Servo Z axis Z phase home enable
Servo 4 axes Z phase home enable
Servo B axis Z phase home enable
Servo C axis Z phase home enable
Range
:
0~1
Unit
:
LOGIC VOLTAGE LEVEL
Authority
:
Super admin
Default
:
0
Effective time
:
Instant
Note
:
When this parameter is enabled, encoder Z phase positioning of
corresponding axis will be enabled automatically in mechanical home
mode, i.e. the “servo home” positioning; in this mode, the accuracy of
repeated home positioning depends on servo positioning accuracy, and
therefore it is recommended to enable this function for servo motor. Step
motor doesn’t have encoder and can’t enable this option, or else the
signals can’t be scanned during mechanical home operation and will
move constantly.
0016
Effective voltage level for servo X axis Z phase
Effective voltage level for servo Y axis Z phase
Effective voltage level for servo Z axis Z phase
Effective voltage level for servo A axis Z phase
Effective voltage level for servo B axis Z phase
Effective voltage level for servo C axis Z phase