ADTECH4 SeriesCNC Maintenance Manual
When mechanical home mode is selected, this parameter determines
whether external deceleration switch should be searched. If this parameter
is set to 0, and P2.015 (servo Z phase enable) is also set to 0, the home
mode sets current point as the home directly in mechanical mode.
0: No
1: Yes
X axis encoder pulse logic direction
Y axis encoder pulse logic direction
Z axis encoder pulse logic direction
4 axes encoder pulse logic direction
B axis encoder pulse logic direction
C axis encoder pulse logic direction
If the logic direction obtained by the encoder is reverse to the actual
motion direction of the axis, please set this parameter.
0: Positive
1: Negative
X axis home deceleration speed
Y axis home deceleration speed
Z axis home deceleration speed
4 axes home deceleration speed
B axis home deceleration speed