Milling Machine Series
CNC operations
131
Advantech-LNC Technology Co., Ltd.
1.8.8 System data backup - export
This system data backup function can only be accessed by users with ﹛Advanced user﹜ permission or above,
which is L3.
Due to safety concerns, the emergency stop 〔EMG-STOP〕 button on the controller's OP panel must be pressed
for the machine to be in "Not ready" status before the backup function can be executed.
After inserting a USB device and pressing the <MAINTE> key on the controller's MDI panel, the 【Backup】 key
on the controller's human machine page can be pressed to enter the system data backup page.