GPIB OPERATION
3-2-19
WIDEBAND FM
WBFM
Set WBFM deviation (short form)
:DEVN Set WBFM deviation
Data type :
Decimal Numeric Program Data
Allowed suffices : Any one of: GHZ, MHZ, KHZ or HZ
Default suffix : HZ
:ON
Turn WBFM ON (local)
:OFF Turn WBFM OFF (local)
:AC Select AC coupling
:DC Select DC coupling
Data type :
None
Allowed suffices : None
Default suffix : None
DCFMNL
Perform DC FM/WBFM null operation
Examples:
WBFM:DEVN 10MHZ;ON;AC
WBFM:DEVN 13MHZ;ON;DC;:DCFMNL
WBFM?
Prepares message containing information on Wideband
Frequency Modulation setting in the following format:
:WBFM:DEVN <nr2>;<coupling>;<status>
where <coupling> is a program mnemonic indicating AC o
r
DC coupling of the modulation signal and <status> is
a program mnemonic indicating whether the
modulation is locally ON or OFF
Example:
:WBFM:DEVN 500000.0;AC;ON