OPTION 006 Avionics
Annex-B-20
ILS (Instrument Landing System) mode
SDM Set Sum of Depth of Modulation (short form)
:DEPTH
:INC
Set SDM Depth
Set SDM step size
Data type : Decimal Numeric Program Data
Allowed suffices : PCT
Default suffix : PCT
:UP
:DN
:RETN
:XFER
Go UP one step
Go DOWN one step
Return to original setting
Transfer current value to be the new setting
Data type : None
Allowed suffices : None
Default suffix : None
Example:
SDM:DEPTH 40PCT;INC 2;UP;UP;UP
:PHASE Specify the phase relationship between the 90 Hz and 150 Hz
tones.
Data type : Character Program Data (any one of SIN_SIN, COS_COS or
SIN_COS).
Allowed suffices : None
Default suffix : None
Example:
SDM:PHASE SIN_COS
SDM?
Prepares messages containing information on SDM in the
following format:
:SDM:DEPTH <nr2>;INC <nr2>
Example:
:SDM:DEPTH 40.0;INC 0.5
SDM:PHASE?
Prepares messages containing information on the phase
relationship between the 90 Hz and 150 Hz tones in the format:
:SDM:PHASE <char>
Example:
:SDM:PHASE SIN_COS
DDM90 Set Difference in Depth of Modulation with 90 Hz tone
predominant (short form)
:DEPTH Set DDM90 Depth
DDM150 Set Difference in Depth of Modulation with 150 Hz tone
predominant (short form)
:DEPTH Set DDM150 Depth
DDM90 or DDM150
:INC
Data type : Decimal Numeric Program Data
Allowed suffices : PCT
Default suffix : None
Note...
When there is no suffix it is assumed that the entry is in
DDM index (%/100).