ACCEPTANCE TESTING
5-1-19
FM scale shape
(1) With the test equipment connected as in Fig. 5-1-9, set the UUT to
[Carrier Freq.] 31.64 MHz [RF Level] 0 dBm [FM Devn.] 224 kHz.
(2) Referring to Table 5-1-14, measure the FM on the modulation meter at the
deviations indicated.
Table 5-1-14 FM scale shape deviations
Deviation (kHz)
224 256 289
228 261 293
233 265 298
238 270 302
242 275 307
247 279 312
252 284 316