EasyManuals Logo

Aeroflex 2030 Series User Manual

Aeroflex 2030 Series
351 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #316 background imageLoading...
Page #316 background image
OPTION 008 RF PROFILES AND COMPLEX SWEEP
Annex-C-23
RF offsets
The GPIB commands for RF LEVEL OFFSETS are as follows:
RFLV
:OFFS [not used alone]
:NUM Select RF Offset (1-5)
Data type: Decimal Numeric Program Data
Allowed Suffices: None
Default Suffix: None
:VALUE Set current RF Offset value
Data type: Decimal Numeric Program Data
Allowed Suffices: dB
Default Suffix: dB
:ENABLE Enable Selected RF Offset
:DISABLE Disable Selected RF Offset
:SAVE Store RF Offsets and status in non-volatile memory
Data type: None
Allowed Suffices: None
Default Suffix: None
RFLV:OFFS?
Responds with RF Offset Selected, its Value and its Status as
follows:
:RFLV:OFFS:NUM <nr1>;VALUE <nrf>;<status>
Example: :RFLV:OFFS:NUM 3;VALUE -40.0;ENABLE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Aeroflex 2030 Series and is the answer not in the manual?

Aeroflex 2030 Series Specifications

General IconGeneral
BrandAeroflex
Model2030 Series
CategoryPortable Generator
LanguageEnglish

Related product manuals