GPIB OPERATION
3-2-39
ERROR?
Prepares message containing the number of the next error in
the error queue in the following format:
<nr1>
The numeric value returned is either that of the next error
number or 0 if the queue is empty or 255 if the queue is full
Example:
37
DEVTRG
Set Device Trigger Function (action on receipt of *TRG)
Data type :
Character Program Data (any one of: SEQT, FLSWP, SSSWP
or VOID)
Allowed suffices : None
Default suffix : None
EXTTRG
Set External Trigger Function (action on Low signal being
applied to External Trigger Socket).
Data type :
Character Program Data (any one of: SEQT, FLSWP, SSSWP,
MEMUP, MEMDN or VOID)
Allowed suffices : None
Default suffix : None
Examples:
DEVTRG SEQT
EXTTRG MEMUP
KLOCK
Disables keyboard entry except RPP Reset and Go to Local
Data type :
None
Allowed suffices : None
Default suffix : None
KUNLOCK
Enables keyboard entry
Data type :
None
Allowed suffices : None
Default suffix : None