OPTION 010 DME Modulator
Annex-E-11
Data type:
Decimal Numeric Program Data
Allowed suffices:
Any one of: ms, us, ns
Default suffix:
ns
Example: DME:RISE 2.5US
:FALL Set DME pulse fall time
Data type:
Decimal Numeric Program Data
Allowed suffices:
Any one of: ms, us, ns
Default suffix:
ns
Example: DME:WIDTH 2.5US
:RATE Set DME pulse pairs/second
Data type:
Decimal Numeric Program Data
Allowed suffices:
None
Default suffix:
None
Example: DME:RATE 6000
DME? Prepares message containing information on the DME
configuration in the following format:
DME:TRIGGER<status>;PPS<nr1>;WIDTH<nr1>;RISE<nr1>;
FALL<nr1>;RATE<nr1>
where:<status> is a program mnemonic indicating whether the
trigger is INTERNAL or EXTERNAL.
Examples: :DME:TRIGGER INTERNAL;PPS 12000;WIDTH 3500;RISE 2500;
FALL 2500;RATE 6000
:DME:TRIGGER EXTERNAL;PPS 24000;WIDTH 4000;RISE 2850;
FALL 2850