106 7713395 R2
Figure 126. SAMPLING is DONE
Have the samples tested for ACTUAL grain moisture content.
Average the values for the ACTUAL grain moisture content.
Enter the calculated average for the actual grain moisture content using the SAMPLE TEST MOISTURE
button.
Tap the DONE button.
A new CURRENT READING is calculated and displayed. The new value will move closer to the TEST
MOISTURE value at a maximum of 0.5 per calibration when the difference is greater than 1.0. If the
difference is less than 1.0 the value will move half way closer (difference 0.8 then moves 0.4).
E.g. In the example shown, the CURRENT READING value was originally 21.6
The SAMPLE TEST MOISTURE average of measured values was 24.5
Since 24.5 21.6 is more than 1.0, the new CURRENT READING moved closer to the SAMPLE TEST
MOISTURE value by 0.5 (from 21.6 to 22.1
Figure 127. CURRENT READING updated after entering SAMPLE TEST MOISTURE averge
4. OPERATION CONTINUOUS MIXED-FLOW GRAIN DRYER WITH COMMANDER CONTROL SYSTEM