150 7713395 R2
Note
The use of this app allows remote access to monitor, make minor operational setting changes and to
stop the dryer only. Starting of equipment must be performed at the dryer HMI panel.
The local operator (User, Owner or NecoTech) via the HMI must start and get the dryer and associated
equipment in the desire state of operation.
Once all equipment is running as desired, the local operator enables remote access
MAIN MENU > SETUP > SECURITY SETUP > I ACCEPT > ENABLE REMOTE ACCESS.
When the “ENABLE REMOTE ACCESS” icon is pressed the current operator is logged out and the “Remote” user
is logged in on the HMI.
The user is now able to access the dryer control via the Vijeo Design’Air app.
Press the app icon on the tablet / phone, then press “NECO dryer”.
Read accept the liability statement. Press “OK” or “View-only” icon.
Login.
Username: RemoteWiFi
Password: 1379
Press “OK”
At this point the tablet / phone displays the same image the HMI screen.
The operator may remotely:
change Burner Temperature(s)
change Target Moisture
change Manual Metering Speed Setpoint
and view all screens
Note
If the “LOGOUT” icon is pressed the dryer control will not be able accessible until operator locally re-
enables the remote access.
8.13. Dryer Temperature Considerations
High-Limit Temperature Consideration
Fire Hazard
In cases where the grain has a lot of trash, or when drying high moisture grain (that is
immature or frozen grain), drying at these temperatures may not be possible, as the risk of
fire is increased..
In cases where there is blockage in the machine due to trash, it is possible for this material
to become subject to spontaneous combustion.
Shut the blower(s) OFF immediately in ANY case where a person may see smoke coming
from the machine.
When the High Temperature Limit alarm is activated, the equipment will immediately shut down with NO
cool-down period (blowers OFF).