7713395 R2 59
Figure 69. Plug Switch Drag
3.10. External Transport(s)
NECO provides the ability to control any combination up to two transport devices to FILL (wet grain) the dryer
and two transport devices to EMPTY (dry grain) the dryer within the Commander Control system. All motor
starters, starter coils, and overload contacts required are customer-supplied.
Depending on what type of transport style and configuration, the necessary data inputs must be entered in the
Fill/Empty setup routine (see Section 4.3.4 – Dealer or Customer Entered Setup Data on page 73). These data
inputs consist of:
Is a motor present that needs to be controlled?
PRESENT
Does that motor need to run continuous?
RUN CONTINUOUS
Does that motor need to stop after drying stops (2
minute delay)?
STOP DRYING AFTER STOPS
Start delay (seconds)?
START DELAY
Stop delay (seconds)?
STOP DELAY
The control integrates the external transport equipment actions depending on the presence of the following
switches:
• Wet bin empty switch
• Dry bin full switch
• Low Level switch
See Section 8.2 – Optional External Transport Configurations on page 128
CONTINUOUS MIXED-FLOW GRAIN DRYER WITH COMMANDER CONTROL SYSTEM 3. FEATURES