© Agilent Technologies 2001–2003 Agilent 3070 System Installation Manual (MS Windows Version) 2-11
Chapter 2: MS Windows System Installation Reference: Editing Files
3 Open the system config file
in a new BT-BASIC window:
•At the new BT-BASIC window command line, enter:
get btgetenv$ ("AGILENT3070_ROOT") & "/diagnostics/th1/config"
4 Arrange the two BT-BASIC
windows so that each can be
readily accessed.
5 Copy the appropriate
statements from the system
config file to the clipboard
buffer:
In the BT-BASIC window containing the system config file:
a Press F1 on the keyboard to enter the workspace.
b Locate the module <number> that contains un-commented
cards 1 ... statements using the arrow keys or the Prev and Next keys.
c Scroll the text up until the end module statement is visible.
d Click and drag with the mouse to highlight the text including the ports ...
statement
The highlighted text is now copied in the clipboard buffer.
NOTE
Do not include probe, debug port, bank, or end bank statements.
These statements are not valid in the standard config file.
Table 2-6 Resolve the standard config file from the system config file (continued)
Task Step

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 3070 and is the answer not in the manual?

Agilent Technologies 3070 Specifications

General IconGeneral
BrandAgilent Technologies
Model3070
CategoryTest Equipment
LanguageEnglish

Related product manuals