MPLS Commands
Page 128 7210 SAS M, T, X, R6, Mxp MPLS Configuration
Guide
Parameters interval — Specifies the hold-up dampening timer interval.
Values 0 — 500 deciseconds, in 100 ms increments
Default 2 seconds
bfd-template
Syntax bfd-template name
no bfd-template
Context config>router>mpls>mpls-tp>oam-template
Description Platforms Supported: 7210 SAS-T network mode and 7210 SAS-R6 devices.
This command configures a named BFD template to be referenced by an OAM template.
Default no bfd-template
Parameters name — Specifies the BFD template name as a text string up to 32 characters in printable 7-bit
ASCII, enclosed in double quotes.
Values
protection-template
Syntax protection-template name
no protection-template
Context config>router>mpls>mpls-tp
Description Platforms Supported: 7210 SAS-T network mode and 7210 SAS-R6 devices.
Protection templates are used to define generally applicable protection parameters for MPLS-TP
tunnels. Only linear protection is supported, and so the application of a named template to an MPLS-
TP LSP implies that linear protection is used. A protection template is applied under the MEP context
of the protect-path of an MPLS-TP LSP.
The protection-template command creates or edits a named protection template.
Default no protection-template
Parameters name — Specifies the protection template name as a text string of up to 32 characters in printable 7-
bit ASCII, enclosed in double quotes.
revertive
Syntax [no] revertive
Context config>router>mpls>mpls-tp>protection-template
Description Platforms Supported: 7210 SAS-T network mode and 7210 SAS-R6 devices.