MPLS and RSVP
7210 SAS M, T, X, R6, Mxp MPLS Configuration Guide Page 129
This command configured revertive behavior for MPLS-TP linear protection. The protect-tp-path
MEP must be in the shutdown state for of the MPLS-TP LSPs referencing this protection template in
order to change the revertve parameter.
Default revertive
wait-to-restore
Syntax wait-to-restore interval
no wait-to-restore
Context config>router>mpls>mpls-tp>protection-template
Description Platforms Supported: 7210 SAS-T network mode and 7210 SAS-R6 devices.
This command configures the WTR timer. It determines how long to wait until the active path of an
MPLS-TP LSP is restored to the working path following the clearing of a defect on the working path.
It is appliable to revertive mode, only.
Default no wait-to-restore
Parameters interval — Specifies the WTR timer interval.
Values 0 — 720 seconds in 1 second increments
rapid-psc-timer
Syntax rapid-psc-timer interval
no rapid-psc-timer
Context config>router>mpls>mpls-tp>protection-template
Description Platforms Supported: 7210 SAS-T network mode and 7210 SAS-R6 devices.
This command configures the rapid timer value to be used for protection switching coordination
(PSC) packets for MPLS-TP linear protection (RFC 6378).
Default no rapid-psc-timer
Parameters interval — Specifies the rapid timer interval.
Values [10, 100, 1000 ms]
Default 10 ms

Table of Contents

Other manuals for Alcatel-Lucent 7210 SAS M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent 7210 SAS M and is the answer not in the manual?

Alcatel-Lucent 7210 SAS M Specifications

General IconGeneral
BrandAlcatel-Lucent
Model7210 SAS M
CategorySwitch
LanguageEnglish

Related product manuals