RADIUS Client Commands
Page 182 7450 ESS System Mangement Guide
shutdown
Syntax [no] shutdown
Context config>system>security>radius
Description This command administratively disables the RADIUS protocol operation. Shutting down the protocol
does not remove or change the configuration other than the administrative state.
The operational state of the entity is disabled as well as the operational state of any entities contained
within. Many objects must be shut down before they may be deleted.
The no form of the command administratively enables the protocol which is the default state.
Default no shutdown
timeout
Syntax timeout seconds
no timeout
Context config>system>security>radius
Description This command configures the number of seconds the router waits for a response from a RADIUS
server.
The no form of the command reverts to the default value.
Default 3 seconds
Parameters seconds — The number of seconds the router waits for a response from a RADIUS server, expressed
as a decimal integer.
Values 1 — 90
use-default-template
Syntax [no] use-default-template
Context config>system>security>radius
Description This command specifies whether the RADIUS user template is actively applied to the RADIUS user
if no VSAs are returned with the auth-accept from the RADIUS server. When enabled, the RADIUS
user template is actively applied if no VSAs are returned with the auth-accept from the RADIUS
server.
The no form of the command disables the command.