SNMP
7450 ESS System Mangement Guide Page 295
Configuring a Community String
SNMPv1 and SNMPv2c community strings are used to define the relationship between an SNMP
manager and agent. The community string acts like a password to permit access to the agent. The
access granted with a community string is restricted to the scope of the configured group.
One or more of these characteristics associated with the string can be specified:
Read-only, read-write, and read-write-all permission for the MIB objects accessible to the
community.
The SNMP version, SNMPv1 or SNMPv2c.
Default access features are pre-configured by the agent for SNMPv1/SNMPv2c.
Use the following CLI syntax to configure community options:
CLI Syntax: config>system>security>snmp
community community-string access-permissions [version SNMP
version]
The following displays an SNMP community configuration example:
*A:cses-A13>config>system>security>snmp# info
----------------------------------------------
community "uTdc9j48PBRkxn5DcSjchk" hash2 rwa version both
community "Lla.RtAyRW2" hash2 r version v2c
community "r0a159kIOfg" hash2 r version both
----------------------------------------------
*A:cses-A13>config>system>security>snmp#
Configuring View Options
Use the following CLI syntax to configure view options:
CLI Syntax: config>system>security>snmp
view view-name subtree oid-value
mask mask-value [type {included|excluded}]
The following displays a view configuration example:
*A:cses-A13>config>system>security>snmp# info
----------------------------------------------
view "testview" subtree "1"
mask ff
exit
view "testview" subtree "1.3.6.1.2"
mask ff type excluded
exit

Table of Contents