Accounting Policy Commands
Page 504 7450 ESS System Mangement Guide
Accounting Policy Custom Record Commands
collection-interval
Syntax collection-interval minutes
no collection-interval
Context config>log>acct-policy
Description This command configures the accounting collection interval.
The no form of the command returns the value to the default.
Default 60
Parameters minutes — Specifies the collection interval in minutes.
Values 5 — 120
custom-record
Syntax [no] custom-record
Context config>log>acct-policy
Description This command enables the context to configure the layout and setting for a custom accounting record
associated with this accounting policy.
The no form of the command reverts the configured values to the defaults.
aa-specific
Syntax [no] aa-specific
Context config>log>acct-policy>cr
Description This command enables the context to configure information for this custom record.
The no form of the command

Table of Contents