Rockwell Automation Publication 20B-IN026C-EN-P - October 2015 25
Basic Component Removal Procedures Chapter 2
6. Remove the two mounting screws below TB11.
7. Remove Main Control Panel; support.
8. Disconnect wire harnesses from TB11 to:
a. J4 on the Switch Mode Power Supply Board.
b. TB1 and TB2 on the Power Interface Board.
9. Label and remove all customer wiring from TB11.
10. Carefully set the Main Control Panel aside.
Install Components
1. Reinstall the Main Control Panel Assembly components in the reverse
order of removal.
2. Torque panel mounting screws to 2.9 N•m (26 lb•in).
3. Replace all safety shields and enclosure covers before applying power to the
drive.