II-9
REMOVING SHIPPING BRACKETS
T
o prevent damage to the machine
during transportation, the table and
the upper sawb lade guide are
secured with the shipping brackets.
After the machine is installed,
remove the bolts securing the
shipping brackets, and remove the
shipping brackets.
NOTICE
O Store the removed shipping brackets and bolts for future use when relocating
the machine.
SUPPLYING HYDRAULIC OIL
Remove the two screws, hydraulic
unit cover, and filler cap. Fill the
hydraulic oil tank to the middle level
of the sight gauge through the filler
with one of the hydraulic oils
recommended below. When the
tank is filled with the specified
amount of the hydraulic oil, replace
the filler cap. Replace and screw
the cover of the hydraulic unit after
the electrical connections are
completed as described later.
SIGHT GAUGE
Recommended hydraulic oils: Esso Teresso 32
Mobil DTE 24
Shell Tellus Oil 32
(ISO VG32 equivalent)
Tank capacity: 10 L {2.6 US gal}
NOTICE
O The hydraulic pump may be damaged if its motor is started without the tank
filled to the specified level.
O The oil discharge rate of the hydraulic pump is adjusted at the time of factory
shipment. Do not tamper with it. If you have a problem, contact AMADA.