EasyManuals Logo

Ametek SEQUOIA Series Programming Manual

Ametek SEQUOIA Series
231 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #119 background imageLoading...
Page #119 background image
Sequoia Series 119
VOLTage:SLEW
Phase Selectable
This command sets the slew rate for all programmed changes in the output voltage level of the source.
A parameter of MAXimum will set the slew to its maximum possible rate. The SCPI representation for
MAXimum is 1E9.
Command Syntax [SOURce:]VOLTage:SLEW[:IMMediate]<NRf+>
Parameters 0 to1E9 | MAX
Unit V/S (volts per second)
*RST Value MAX
Examples VOLT:SLEW 1 VOLT:SLEW MAX
Query Syntax [SOURce:]VOLTage:SLEW[:IMMediate]?
Returned Parameters <NR3>
Related Commands VOLT:SLEW:MODE VOLT:SLEW:TRIG
VOLTage:SLEW:MODE
Phase Selectable
This command determines how the output voltage slew rate is controlled during a triggered output
transient. The choices are:
FIXed The slew rate is unaffected by a triggered output transient.
STEP The slew rate is programmed to the value set by VOLTage:SLEW:TRIGgered
when a triggered transient occurs.
PULSe The slew rate is changed to the value set by VOLTage:SLEW:TRIGgered for
a duration determined by the pulse commands.
LIST The slew rate is controlled by the voltage slew list when a triggered transient
occurs.
Command Syntax [SOURce:]VOLTage:SLEW:MODE<mode>
Parameters FIXed | STEP | PULSe | LIST
*RST Value FIX
Examples VOLT:SLEW:MODE LIST VOLT:SLEW:MODE FIX
Query Syntax [SOURce:]VOLTage:SLEW:MODE?
Returned Parameters <CRD>
Related Commands VOLT:SLEW:TRG VOLT:SLEW
VOLTage:SLEW:TRIGgered
Phase Selectable
This command selects the slew rate that will be set during a triggered step or pulse transient. A
parameter of MAXimum will set the slew to its maximum possible rate. The maximum allowed value
is1E9.
Command Syntax [SOURce:]VOLTage:SLEW:TRIGgered<NRf+>
Parameters 0 to 1E9 | MAXimum
Unit V/S (volts per second)
*RST Value MAXimum
Examples VOLT:SLEW:TRIG 1 VOLT:SLEW:TRIG MAX
Query Syntax [SOURce:]VOLTage:SLEW:TRIGgered?
Returned Parameters <NR2>
Related Commands VOLT:SLEW:MODE VOLT:SLEW

Table of Contents

Other manuals for Ametek SEQUOIA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ametek SEQUOIA Series and is the answer not in the manual?

Ametek SEQUOIA Series Specifications

General IconGeneral
BrandAmetek
ModelSEQUOIA Series
CategoryPortable Generator
LanguageEnglish

Related product manuals