STATus:OPERation:EVENt?
This query returns the value of the Operation Event register. The Event register is a read-only register,
which holds (latches) all events. Reading the Operation Event register clears it.
Query Syntax STATus:OPERation:EVENt?
Parameters None
Returned Parameters <NR1>(Register Value)
Examples STAT:OPER:EVEN?
Related Commands *CLS
STATus:OPERation:CONDition?
This query returns the value of the Operation Condition register. This is a read-only register, which
holds the real-time (unlatched) operational status of the power source.
Query Syntax STATus:OPERation:CONDition?
Parameters None
Examples STAT:OPER:COND?
Returned Parameters <NR1>(Register value)
STATus:OPERation:ENABle
This command and its query set and read the value of the Operation Enable register. This register is
a mask for enabling specific bits from the Operation Event register to set the operation summary bit
(OPER) of the Status Byte register. The operation summary bit is the logical OR of all enabled
Operation Event register bits.
Command Syntax STATus:OPERation:ENABle <NRf+>
Parameters 0 to 32727
Default Value 0
Examples STAT:OPER:ENAB 32
STAT:OPER:ENAB 1
Query Syntax STATus:OPERation:ENABle?
Returned Parameters <NR1>(Register value)
Related Commands STAT:OPER:EVEN

Table of Contents

Other manuals for Ametek SEQUOIA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ametek SEQUOIA Series and is the answer not in the manual?

Ametek SEQUOIA Series Specifications

General IconGeneral
BrandAmetek
ModelSEQUOIA Series
CategoryPortable Generator
LanguageEnglish

Related product manuals