VF over voltage protection has tripped
CF over-current protection has tripped
PCL Peak current fault
OT over-temperature protection has tripped
UNR Unregulated voltage
AC Fault AC Module fault
UVP Undervoltage protection tripped
AUX Down Auxiliary down
EXT OVP External reference voltage exceed limit
RI remote inhibit is active
PFC Fault Boost module fault
DC Fault DC to DC module fault
CL rms current limit is active
STATus:QUEStionable[:EVENt]?
This query returns the value of the Questionable Event register. The Event register is a read-only
register which holds (latches) all events. Reading the Questionable Event register clears it.
Query Syntax STATus:QUEStionable[:EVENt]?
Parameters None
Returned Parameters <NR1>(Register Value)
Examples STAT:QUES:EVEN?
Related Commands *CLS
STATus:QUEStionable:CONDition?
This query returns the value of the Questionable Condition register. This is a read-only register which
holds the real-time (unlatched) questionable status of the power source.
Query Syntax STATus:QUEStionable:CONDition?
Example STAT:QUES:COND?
Returned Parameters <NR1>(Register value)