EasyManuals Logo

Ametek SEQUOIA Series Programming Manual

Ametek SEQUOIA Series
231 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #190 background imageLoading...
Page #190 background image
190 Sequoia Series
:IHARmonics
:LEVel Set interharmonics level.
:DWELl Set interharmonics dwell.
:PAUSe Set interharmonics pause.
IEC413:STATe
This command will enable the IEC413 and initialize the associated data. Note that user defined test
levels for the USER group can only be programmed when the IEC413 state is OFF.
Command Syntax IEC413:STATe <state>
Parameters <ON|OFF|1|0 >
Examples IEC413:RUN STAT ON
Query Syntax IEC413:STAT?
Returned Parameters <boolean>
IEC413:RUN
This command will run the test. The parameters will define the section of test to be run.
Command Syntax IEC413:RUN <group>
Parameters < ALL|GROup|RANGe|POINt >
Examples IEC413:RUN ALL
Query Syntax IEC413:RUN?
Returned Parameters <group>
IEC413:PAUSe
This command will cause the test to pause at the time the command is issued.
Command Syntax IEC413:PAUSe <boolean>
Parameters ON|OFF|1|0
Examples IEC413:PAUS ON
Query Syntax IEC413:PAUS?
Returned Parameters <boolean>
IEC413:CLASs
This command will select the class. There are two predefined classes 2 and 3. Class 1 is supported
through the use of the USER defined class. Other tests levels can be set in the USER class as well.
Command Syntax IEC413:CLASs <class>
Parameters 2|3|USER
Examples IEC413:CLAS 3
Query Syntax IEC413:CLAS?
Returned Parameters <class>

Table of Contents

Other manuals for Ametek SEQUOIA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ametek SEQUOIA Series and is the answer not in the manual?

Ametek SEQUOIA Series Specifications

General IconGeneral
BrandAmetek
ModelSEQUOIA Series
CategoryPortable Generator
LanguageEnglish

Related product manuals