198 Sequoia Series
IEC413:IHARmonics:DWELl
This command will set the dwell time in seconds for each interharmonics frequency. The class must
be selected prior to this command. Query with min and max to find the range of the dwell time.
Command Syntax IEC413: IHARmonics:DWELl <NRf+>
Parameters <seconds>
Examples IEC413:IHAR:DWEL 15
Query Syntax IEC413:IHAR:DWEL?
Returned Parameters <NR1>
IEC413:IHARmonics:PAUSe
This command will set the pause time in seconds between each interharmonics frequency. The class
must be selected prior to this command. Query with min and max to find the range of the pause time.
Command Syntax IEC413: IHARmonics:PAUSe <NRf+>
Parameters <seconds>
Examples IEC413:IHAR:PAUS 2
Query Syntax IEC413:IHAR:PAUS?
Returned Parameters <NR1>