220 Sequoia Series
Number
Message String
Cause
Remedy
-128
"Numeric data not
allowed"
Number received, but
is not allowed
Check Programming Manual for
correct command syntax.
-168
"Block data not
allowed"
Block data received,
but is not allowed
Check Programming Manual for
correct command syntax.
-200
"Execution error"
Command could not
be executed
Command might be inconsistent with
mode of operation, such as
programming frequency when in
DC-Mode.
-201
"Invalid while in local"
Command issued but
unit is not in remote
state
Put instrument in remote state before
issuing SCPI commands.
-203
"Command protected"
Command is locked
out
Some commands are supported by
the unit but are locked out for
protection of settings and are not user
accessible.
-210
"Trigger error"
Problem with trigger
system
Unit could not generate trigger for
transient execution or measurement.
-211
"Trigger ignored"
Trigger request has
been ignored
Trigger setup incorrect or unit was not
armed when trigger was received.
Check transient system or
measurement trigger system settings.
-213
"Init ignored"
Initiation request has
been ignored
Unit was told to go to armed state but
was unable to do so. Could be caused
by incorrect transient system or
measurement acquisition setup.
-220
"Parameter error"
Parameter not
allowed
Incorrect parameter or parameter
value. Check Programming Manual for
allowable parameters.
-221
"Setting conflict"
Requested setting
conflicts with other
settings in effect
Check settings: e.g., changing mode,
AC/DC/AC+DC, is not allowed with
output on; setting voltage is not
allowed if reference is not internal;
setting frequency is not allowed if set
for External SYNC or Clock/Lock.
-222
"Data out of range"
Parameter data
outside of allowable
range
Check Programming Manual for
allowable parameter values.
-223
"Too much data"
More data received
than expected
Check Programming Manual for
number of parameters or data block
size.
-224
"Illegal parameter
value"
Parameter value is not
supported
Check Programming Manual for
correct parameters.
-226
"Lists not same length"
One or more transient
lists programmed has
different length
All lists must be of same length or
transient cannot be compiled and
executed.
-254
"Media full"
No storage space left
to save settings or
data
Delete other settings or data to make
room.
-255
“Directory full”
Too many waveform
directory entries
Delete one or more waveforms from
waveform memory to make room.
-256
“File name not found”
Waveform requested
not in directory
Check waveform directory for
waveform names present.

Table of Contents

Other manuals for Ametek SEQUOIA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ametek SEQUOIA Series and is the answer not in the manual?

Ametek SEQUOIA Series Specifications

General IconGeneral
BrandAmetek
ModelSEQUOIA Series
CategoryPortable Generator
LanguageEnglish

Related product manuals