222 Sequoia Series
Number
Message String
Cause
Remedy
4
"External sync. error"
Could not sync to
external sync signal
External sync signal missing,
disconnected or out of range.
5
"Initial memory lost"
Power-on settings
could not be recalled.
Save power-on settings again to
overwrite old content.
6
"Limit memory lost"
Hardware
configuration settings
lost
Contact AMETEK Service Department
to obtain instructions on restoring
configuration data.
7
"System memory lost"
Memory corrupted
Recycle power. Contact AMETEK
Service Department for instructions if
memory remains corrupted.
8
"Calibration memory
lost"
Calibration data lost
Contact AMETEK Service Department
to obtain instructions on restoring
calibration data or recalibrate unit.
9
"Start angle must be
first sequence"
Start phase angle in
wrong place
Start phase angles can only be
programmed at the start of a transient
list. Once a transient is in progress,
phase angle cannot be changed.
10
"Illegal for DC"
Operation not
possible in DC-Mode
Switch to AC or AC+DC mode.
11
“Duplicate sequence”
Transient list
sequence number
already used
Use new or available sequence
number.
12
“Too many sequence”
Number of transient
list steps exceeds
maximum
Reduce the number of steps in the
transient list to maximum of 100.
13
"Missing list parameter"
One or more transient
list parameters
missing
Check programmed lists.
14
"Voltage peak error "
Peak voltage
exceeded
This error could occur when selecting
user-defined wave shapes with higher
crest factors. Reduce programmed
RMS value.
16
"Illegal during
transient"
Operation requested
not available while
transient is running
Wait until transient execution is
completed or abort transient execution
first.
17
"Output relay must be
closed"
Operation not
possible with open
relay
Close relay before attempting
operation: e.g., transient execution
requires output relay to be closed.
18
"Trans. duration less
then 0.5msec"
Dwell time below
minimum of 0.5 ms
Increase dwell time to at least 0.5 ms.
19
"Clock and sync must
be internal"
Operation not
possible with external
clock
Switch to internal sync (default).
20
"Input buffer full"
Too much data
received
Break up data in smaller blocks.
21
“Timeout error”
Controller did not
receive command
from the display
Reduce remote command activity.
Internal communication between
controller and display has been
impacted.
22
"Waveform harmonics
limit"
Harmonic content of
user-defined wave
Reduce harmonic content or reduce
the programmed fundamental
frequency.

Table of Contents

Other manuals for Ametek SEQUOIA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ametek SEQUOIA Series and is the answer not in the manual?

Ametek SEQUOIA Series Specifications

General IconGeneral
BrandAmetek
ModelSEQUOIA Series
CategoryPortable Generator
LanguageEnglish

Related product manuals