Sequoia Series 47
4.2.15 Monitor
CALibration:MONitor:VOLTage[ :FSCale] <NRf>
This command will result in the Calibrate the coefficient for Voltage Monitor VMON
Command Syntax CALibration:MONitor:VOLTage <NRf>
Parameters <NRf> (value from 0 to 65535)
Examples CAL:MON:VOLT 35000
Query Syntax CAL:MON:VOLT?
Returned Parameters <NRf> (value from 0 to 65535)
CALibration:MONitor:CURRent[ :FSCale] <NRf>
This command will result in the Calibrate the coefficient for Voltage Monitor IMON
Command Syntax CALibration:MONitor:CURRent <NRf>
Parameters <NRf> (value from 0 to 65535)
Examples CAL:MON:CURR 35000
Query Syntax CAL:MON:CURR?
Returned Parameters <NRf> (value from 0 to 65535)