58 Sequoia Series
MEASure:CURRent:DC?
FETCh:CURRent:DC?
Phase Selectable
These queries return the dc component of the output current being sourced at the output terminals.
This command should be used when the voltage mode of the source is set for DC
Query Syntax MEASure[:SCALar]:CURRent:DC?
FETCh[:SCALar]:CURRent:DC?
Parameters None
Examples MEAS:CURR? FETC:CURR?
Returned Parameters <NR2>
Related Commands INST:NSEL
MEASure:CURRent:AMPLitude:MAXimum?
FETCh:CURRent:AMPLitude:MAXimum?
Phase Selectable
These queries return and hold the absolute value of the peak current as sampled over one
measurement acquisition of 4096 data points. The returned value will be updated only when a larger
value is found. To update the value with every measurement a peak current reset command should
be used prior to the peak measurements.
Query Syntax MEASure[:SCALar]:CURRent:AMPLitude:MAXimum?
FETCh[:SCALar]:CURRent:AMPLitude:MAXimum?
Parameters None
Examples MEAS:CURR:AMPL:MAX? FETC:CURR:AMPL:MAX?
Returned Parameters <NR2>
Related Commands INST:NSEL MEAS:CURR:AMPL:RESet
MEASure:CURRent:AMPLitude:RESet
Phase Selectable
This command will reset the peak current measurement to zero.
Query Syntax MEASure[:SCALar]:CURRent:AMPLitude:RESset.
Parameters None
Examples MEAS:CURR:AMPL:RES
Returned Parameters None
Related Commands MEAS:CURR:AMPL:MAX?

Table of Contents

Other manuals for Ametek SEQUOIA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ametek SEQUOIA Series and is the answer not in the manual?

Ametek SEQUOIA Series Specifications

General IconGeneral
BrandAmetek
ModelSEQUOIA Series
CategoryPortable Generator
LanguageEnglish

Related product manuals