Input modeInput mode
For the switching method between PDH Rx and DSn Rx, refer to Physical Setup
in "E1 Setup and Status". Touch DS3DS3 radio button. Touching OffOff radio button
disables the receiver.
This screen allows you to make the physical setup of the PDH receiver in DS3
mode. It can also be used to inspect the current status of the selected port.
The configuration options available in the setup area of the screen are
described below. The status information is described in a separate section.
Select the mode of input.
TerminateTerminate
Used when the instrument is used as a tester and the receiver is the only
device connected to the line. The input impedance is nominal.
MonitorMonitor
Used when connecting to protected monitoring points. The input impedance
is nominal.
55..66..22..22 DS3 Signal SetupDS3 Signal Setup
Touching the receiver's DS3DS3 button in the navigation area will display the
screen shown below.