33..66 In-band ControlIn-band Control
In-band Control remotely controls the Network Master via a port. This control
method is available when Ethernet application is running in the Network
Master. This allows users to control Network Masters via a device under test or
a network under test, etc.
1. Start Ethernet application except Pass Through and Cable Test without the
OTN layer in Network Master.
2. Set NicknameNickname and In-band TCP portIn-band TCP port in Remote Control.
3. Select Allow In-band controlAllow In-band control in In-band Setup, and set an IP address, etc.
4. Start the Discovery application in Network Master used as a controller.
5. Search for other Network Masters using the Discovery application, and control
them.
In-band Control only switches the application of the Network Master.