39
for customizing how long the receiver will wait for a reply before continuing to scan.
The parameter ranges are off, hold and 0.1 to 9.9 seconds in 0.1 second increments.
(Default: 2.0 seconds)
To set the scan delay parameter, perform the following steps:
1. On the scan group setting screen, use the [] key or [] key to select [DELAY].
2. Rotate the dial knob to select the scan delay.
3. If “HOLD” is selected, the receiver will stop scanning
4. To confirm entry, press the [ENT] key. To set other parameters, press the [] key.
7-5-3 SCAN PAUSE
The scan pause parameter determines how long the receiver will remain on an active channel before
resuming scanning even if the channel is still busy. Scan pause helps keep you from having to manually
intervene to force the scan to continue or use channel lockout (pass).
The parameter ranges are off and 1 to 60 seconds. When the parameter is set to off, the receiver
remains on the busy channel until the received signal disappears or the memory channel is changed.
To set the scan pause parameter, perform the following steps:
1. On the scan group setting screen, use the [] key or [] key to select [FREE].
2. Rotate the dial knob to set scan pause parameter (between 1 ~ 60 or off). To set scan pause to
off (zero), press the [PASS] key or enter “0” from the numeric keypad.
3. To confirm entry, press the [ENT] key.