EasyManuals Logo

APRILIA RSV4 Factory a-PRC 2009 User Manual

APRILIA RSV4 Factory a-PRC 2009
521 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #158 background imageLoading...
Page #158 background image
•
circuit not operational
Error cause
•
Replace injection ECU
Stop lights relay error P0610
•
short circuit to positive/ short circuit to negative / open circuit
Error cause
•
If shorted to positive: excessive voltage has been detected at PIN 31. If shorted to negative:
no voltage has been detected. If the circuit is open: an interruption has been detected
Troubleshooting
•
If shorted to positive: check the relay electrical specifications are correct by disconnecting
it from the cable harness. If they are not correct, replace the relay; if OK, restore the cable
harness (Blue/Pink cable)
•
If shorted to negative: check the relay electrical specifications are correct by disconnecting
it from the cable harness. If they are not correct, replace the relay; if OK, restore the cable
harness (Blue/Pink cable)
•
If the circuit is open: check the relay electrical characteristics are correct by disconnecting
it from the cable harness; if not OK, replace the relay, if OK, check relay connector, engine-
vehicle cable harness connector and ENGINE connector of the Marelli control unit: if not
OK, restore; if OK, check continuity of cable harness (Blue/Pink cable)
DIAGNOSIS INSTRUMENT: LOGIC ERRORS
Level 2 safety reset P0608
Error cause
•
As the level 2 safety system (comparison between requested torque and calculated torque)
has detected a fault, the control unit has reset engine (C gravity). The instrument panel does
not indicate the presence of this error even in the ATT status.
Troubleshooting
•
Continue fault search for the other errors detected
Safety Engine Stop P0609
Error cause
•
Since the safety system has detected a serious fault, the control unit has shut off the engine
Troubleshooting
•
Continue fault search for the other errors detected.
Saved data file (for safety) P0611
•
Filled
Error cause
Electrical system RSV4 Factory a-PRC
ELE SYS - 158

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the APRILIA RSV4 Factory a-PRC 2009 and is the answer not in the manual?

APRILIA RSV4 Factory a-PRC 2009 Specifications

General IconGeneral
BrandAPRILIA
ModelRSV4 Factory a-PRC 2009
CategoryMotorcycle
LanguageEnglish

Related product manuals