ATTILA
EN
76
dEF = Defrosting
PARAMETER DESCRIPTION UM R290
R455a/
R452a
Min Max
En
Enabling defrost function from STOP button in
StandBy [ 0 - disabled, 1 - for Stop, 2 - with fan, 3 -
with resistor, 4 - with fan and resistor ]
2 2 0 4
Prb Chamber temperature detection probe selection 1 1 0 4
dSt Defrost end temperature [0.1°C] 0.1°C 50 50 0 450
dEt Maximum defrosting function time [min] min 20 20 0 100
dl - Digital input management
PARAMETER DESCRIPTION UM R290
R455a/
R452a
Min Max
dCd
Maximum compressor on time with door open
[Seconds]
sec 180 180 0 3000
dEd
Maximum evaporator on time with door open
[Seconds]
sec 0 0 0 3000
dnd
Maximum condenser on time with door open
[Seconds]
sec 180 180 0 3000
dLc
Enabling compressor timeout control from door to
door
1 1 0 1
dLE
Enabling evaporator timeout control from door to
door
1 1 0 1
dLn
Enabling condenser timeout control from door to
door
1 1 0 1
tdO Alarm delay for open door [Seconds] sec 120 120 0 250