Migrating translations
Issue 2.1 June 2006 491
!
CAUTION:
CAUTION: If the information in the Primary Control Subnet Address field is incorrect, you
must change the information on the media server. Use the Maintenance Web
Interface. Under Server Configuration and Upgrades, click Configure Server to
change the media server configuration. Then continue with step 3 of this
procedure.
3. Verify that the Switch Identifier field is set correctly for this installation. You must enter the
correct switch identifier here before you administer the TN2312 IPSI circuit packs.
4. Verify that the IPSI Control of Port Networks field is set to disabled.
5. Press Enter.
Adding IPSI translations to Communication Manager
To add IPSI translations to Communication Manager:
1. Type add ipserver-interface 1. Press Enter to add the IPSI circuit pack information.
2. If you use static addressing, in the Host field, type the IP address for the IPSI that is in the
port network listed in the Location field.
3. Verify that the IP Control? field is set to y.
4. Verify that all the other fields are populated.
5. Press Enter to put the changes into effect.
6. Repeat Steps 1 through 5 for each IPSI.
Setting the alarm activation level
To set the alarm activation level:
1. Type change system-parameters maintenance. Press Enter.
2. In the CPE Alarm Activation Level field, select warning, minor, or major, depending on
the level that the customer wants. The default is none.

Table of Contents

Other manuals for Avaya S8500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Avaya S8500 and is the answer not in the manual?

Avaya S8500 Specifications

General IconGeneral
BrandAvaya
ModelS8500
CategoryServer
LanguageEnglish

Related product manuals