On first S8720 Media Server
Issue 2.1 June 2006 999
Enabling CNC, if necessary
If the CNC status in Checking the CNC status on page 957 is Control Network C was
configured, do this procedure. Otherwise, go to Initializing Communication Manager
on
page 999.
If using Control Network C (CNC):
1. Use the PuTTY application to reaccess the server using the secure shell (SSH) protocol.
2. Log in as craft or dadmin.
3. Type cnc on. Press Enter.
Initializing Communication Manager
To initialize Communication Manager:
1. Use the PuTTY application to reaccess the server using the secure shell (SSH) protocol.
Note:
Note: For the following step, the logons are release-dependent.
2. Log in as craft or dadmin.
3. Type stop -acf. Press Enter to stop Communication Manager.
Communication Manager might already be stopped in Stopping Communication Manager
on the first S8720 Media Server on page 991.
4. Type server -b. Press Enter to queue a busy out of the Communication Manager
software.
The system responds with the following message
ACP not yet running, queueing busyout request.
5. Type start -ac. Press Enter to start Communication Manager and load the translations.
Performing an integrity check on the first S8720 Media Server
To perform an integrity check on the first S8720 Media Server:
1. On the Maintenance Web Interface, under Diagnostics, click Ping.
The system displays the Ping window.