EasyManua.ls Logo

Barber-Colman MACO Series - Figure 6.2 High Spd Ana (Parison) Card Pressure Transducer Wiring; Figure 6.3 High Spd Ana (Parison) Card DC Input and Output Wiring

Default Icon
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1640-IN-031-C-08 Page 45 of 104
MACO Series Controller Installation
Eurotherm/Barber-Colman
Figure 6.2 High Speed Analog (Parison) Card Pressure Transducer Wiring
1. High level excitation is from an external regulated power supply.
2. If the transducer does not have a built-in calibration resistor, insert resistor
as shown between EX(-) and CAL terminal.
3. If resistor is not built-in, use value specified by manufacturer.
Notes:
Figure 6.3 High Speed Analog (Parison) Card DC Input and Output Wiring
Analog In Plus (+)
Analog In Minus (-)
Analog Out (+)
Excitation (+)
Analog Common (-)
Cal A
Cal B
EX+
EX-
Sig-Sig+
internalexternal
or
Wire shield directly to
panel earth ground
DC Input 1
DC Input 2
DC Input 3
DC Input 4
VBIAS (+DC for Outputs)
DC Input/Output Common
DC Output 1
DC Output 2
DC Output 3
DC Output 4
External
Supply
(24 Vdc max)
+
Loads

Table of Contents