Instruction Manual w VERTICUS 5 Compressor Units
D-35
No: RemedyCauseFault message
36 Crankcase pressure min. Gas supply to crankcase low Gas supply to crankcase prüfen bzw. jus
tieren. Refer to compressor operation
manual
37 Crankcase pressure max. Gas supply to crankcase high Check gas supply to crankcase and
adjust setting. Refer to compressor
operation manual
Delivery of blow-by compressor low Check compressor
Delivery of compressor low Check compressor
38 Pressure dew point high pre-
warning
39 Pressure dew point high / filter
lifetime
40 Niveau gas balloon low Gasversorgung der gas balloon low Adjust settings of compressor unit
Delivery of compressor high Adjust settings of compressor unit
41 Niveau gas balloon high Gasversorgung der gas balloon high Adjust settings of compressor unit
Delivery of compressor low Adjust settings of compressor unit
42 Temperature cooling air low Room ventilation unsatisfactory Improve ventilation of the compressor
room. Refer to compressor operation
manual
43 Temperature cooling air high Room ventilation unsatisfactory Improve ventilation of compressor
room. Refer to compressor operation
manual
44 Temperature last stage low Compressor cold Check room temperature and . Refer to
compressor operation manual
Room ventilation unsatisfactory Improve ventilation of compressor
room. Refer to compressor operation
manual
Water cooling setting wrong Check water cooling. Refer to
compressor operation manual
45 Temperature last stage high Compressor defective Contact BAUER service dept.
Room ventilation unsatisfactory Improve ventilation of compressor
room. Refer to compressor operation
manual
Water cooling setting wrong Check water cooling. Refer to
compressor operation manual
46 Temperature stage 1 high Temperature of intake medium high Check temperature of the medium,
cooldown medium. Refer to compressor
operation manual
47 Temperature 2nd stage high
48 Temperature 3rd stage high
49 Temperature 4th stage high
50 Temperature gas outlet high
51 Cooling water temperature
min.
Ambient temperature low (under -30
°C)
Wait until ambient temperature is right