V5−A/05/14
Instruction Manual w VERTICUS 5 Compressor Units
A-3
A. DESCRIPTION
1. GENERAL
1.1. PURPOSE AND SHORT DESCRIPTION
This instruction manual describes the breathing air com
pressor units of the VERTICUS 5 model range:
V 12.14
V 150
V 15.1
V 15.11
V 180
V 18.1
The compressor units are complete units for filling tanks in
the pressure range 200 bar (2,900 psi) and/or 300 bar
(4,300 psi), or 420 bar (6,000 psi), respectively. They are
used mainly to compress air for breathing as required in
diving and fire fighting applications.
The breathing air compressor units are available in two
housing types:
The V series in the open housing
The V series in the Super-Silent housing
The open units can be upgraded to a Super-Silent version
at any time.
The noise level of the Super-Silent units is 69 dB(A) 2 dB(A)
in 1 m distance (according to DIN 45635).
All units are equipped as standard with filter system P61,
TÜV approved final pressure safety valve and manual con
densate drain valves.
Optionally, as described in the following chapters, the units
can be delivered with an integrated filling panel with four
filling hoses, bottle connectors for the specified pressure
range and final pressure gauge, or with external filling pan
els with up to 6 filling hoses for one or two pressure ranges;
filter system P81 for extended cartridge lifetime,
SECURUS monitoring system for the filter system, ACD
(automatic condensate drain unit) with 10 l condensate col
lector tank, optionally 40 ltrs., and with electronic com
pressor control system B-CONTROL with integrated elec
tronic monitoring unit.
Optionally, as described in the following chapters, the units
can be delivered with an integrated filling panel with four
filling hoses, bottle connectors for the specified pressure
range and final pressure gauge, or with external filling pan
els with up to 6 filling hoses for one or two pressure ranges.
1.2. DESIGN AND MODE OF OPERATION
Design
The compressor unit comprises the following major assem
blies:
Compressor block
Drive motor
Frame and housing assembly with instrument panel
Filter set
Automatic condensate drain
Filling panel
a)
Electric control and electronic monitoring system
The design of the compressors is shown in Fig. 1 to Fig. 3.
For special equipment according to order see figures and
parts lists in the annex.
Mode of operation; flow diagram
The path of the air through the compressor system is shown
in the flow diagram. For flow diagram refer to section F of
this manual.
a) optional extra according to order