Display and operation elements
Instruction handbook b maXX BM4400, BM4600, BM4700
Document No.: 5.12008.07 Baumüller Nürnberg GmbH
136
of 358
4.7
4.7.3 Address switch S1 - S4 (only ES controller)
EtherCAT
®
Type code ES controller with EtherCAT
®
:
BM4XXX - XXX - XXXXX[Ryy] - 1X (with EtherCAT
®
interface)
IP address
S1 to S4
The IP address of the controller consists of 32 bits or 4 bytes (e.g. 192.168.125.203). Both
of the first bytes are set with the base address (192.168.) at the factory.
Both of the last bytes are set by means of the address switches S1, S2, S3 and S4. In the
process, S1 and S2 as well as S3 and S4 each represent an 8 bit value.
The IP address 192.168.0.0 is not permitted or, respectively, is reserved.
For information on changing the base address, see the parameter manual.
Example