EasyManua.ls Logo

Baumuller BM4400 - Required Environmental Conditions

Baumuller BM4400
360 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Data
Instruction handbook b maXX BM4400, BM4600, BM4700
Document No.: 5.12008.07
55
of 358
3
3.3.4 Required environmental conditions
Transport temperature range - 25 °C to + 70 °C
Transport climatic category
EN 60721-3-2
2 K 3
Storage temperature range - 25 °C to + 55 °C
Storage climatic class
EN 60721-3-1
1 K 4
Operation environment industrial system
1)
Operation temperature range min. 5 °C to max. 55 °C
(rated temperature 40 °C)
Operation climatic class
EN 60721-3-3
3 K 3
Mounting height
2)
absolute altitude up to 2000 m
Humidity (operation)
EN 60721-3-3
relative humidity: 5 % to 85 % no condensation
and
absolute humidity: 1 g/m
3
to 25 g/m
3
Ionizing and non-ionizing radiation lower than measurable range
Vibration, shock and repetitive shock
EN 61800-5-1, section 5.2.6.4 Vibration test
max. 0.5 g during operation
Degree of pollution
EN 61800-5-1, table 6, Tab. 2
2
1)
For the operation in an environment of category C2 according to IEC 61800-3:2012, additional measures may be required.The manu-
facturer of the installation / user must provide the following evidence in this case:
The additional measures are effective. The specified
limit values of category C2, which are described in IEC 61800-3, are complied with.
2)
See correction factors at environmental conditions, which were changed ZMounting heighton page 56.
NOTICE!
Normally, non-conductive pollution occurs. Conductive pollution is unacceptable.
Conductive pollution can lead to the destruction of the device. The customer is re-
sponsible for destructions, which were caused by pollution due to conductive materi-
als or components.

Table of Contents